Product Features:
Rated Voltage:GTO-10 10KVl GTO-15 15KV
Testing Voltage:GTO-10 20KVl GTO-15 30KV
Rated temp:≤150℃l
Conductor: tinned l copper wire Insulator:Silicone rubberl By the UL1581 VW-1 perpendicular combustion experimentl
Applicable to electric,electrical appliance,lighting etc.high temperaturel high voltage.
Wire Lettering:
GTO-10 INTEGRAL SLEEVE 18AWG(0.823mm²) 150℃ 10000V (UL) C(UL) ROHS GTO-15 INTEGRAL SLEEVE 14AWG(2.08mm²) 150℃ 30000V (UL) C(UL) ROHS GTO-15 INTEGRAL SLEEVE 18AWG(0.823mm²) 150℃ 30000V (UL) C(UL)ROHS
ITEMS |
Technical Datas |
Applied Standard |
appearance |
Smooth even without loose |
UL814
UL879
UL1581 |
Vol. test |
GTO-10 |
20KV/1h |
GTO-15 |
30KV/1h |
insulation
mechanical
character |
Before aging |
Tensile strength |
≥5.5N/mm² |
Break elongation rate |
≥250% |
After aging
(210±1℃×1440h) |
Tensile strength |
60% of the tensile strength before aging |
Break elongation rate |
25% of the elongation rate before aging |
harmful substance control |
COMPLY WITH ROHS |
EU—2002/95/EC |
conductor |
insulation |
Max. conductor resistance
Ω/ km |
Reference weight
Kg/km |
Spec.
AWG |
structure
NO./mm |
Nominal thickness
mm |
Nominal diameter
mm |
allowance
mm |
GTO-10
(18AWG) |
19/0.25 |
2.64 |
6.53 |
±0.20 |
23 |
49 |
GTO-15
(18AWG) |
19/0.25 |
2.70 |
6.80 |
±0.20 |
23 |
54 |
GTO-15
(14AWG) |
42/0.25 |
3.80 |
9.40 |
±0.20 |
9.90 |
102 | |