AWM 3262 Silicone Rubber Insulation Wire |

Product Features:
·Rated Voltage:600V ·Rated temperature:200℃ ·Conductor: bare brass, nickel-coated, tin-coated, silver-coated copper wire
·Insulator: silicone rubber
Wire Lettering: AWM3262(26AWG~20AWG) 200℃ 600V CUL AWM I A 200℃ 600V FT2
Items |
Technical datas |
Applied standard |
Outer appearance |
Smooth, even, without loose |
UL 758
UL 62
UL 1581 |
Spark test |
AC6KV/ 0.15 S |
Vol. test |
2KV/1 min |
mechanical properties of insulation material |
Before aging |
Tensile strength |
≥3.45N/mm² |
elongation at break |
≥100% |
After aging
(210±1℃×1440h) |
Tensile strength |
60% of the tensile strength before aging |
elongation at break |
25% of the elongation before aging |
Poisonous substance control |
Comply with ROHS rule |
EU—2002/95/EC |
AWM 3262 200℃ 600V |
AWG
No. |
section
mm² |
conductor |
insulation |
Wire OD |
conductor resistance 20℃ Ω/KM |
structure
NO./mm |
Dia.
mm |
nominal thick
mm |
Min. thick
mm |
Nominal mm |
Allowance mm |
26 |
0.128 |
7/0.16 |
0.48 |
0.76 |
0.69 |
2.00 |
±0.10 |
188 |
25 |
0.162 |
9/0.16 |
0.56 |
0.76 |
0.69 |
2.08 |
±0.10 |
150 |
24 |
0.205 |
7/0.20 11/0.16 |
0.60 |
0.76 |
0.69 |
2.12 |
±0.10 |
94.2 |
23 |
0.259 |
11/0.18 |
0.70 |
0.76 |
0.69 |
2.22 |
±0.10 |
74.5 |
22 |
0.324 |
7/0.25 13/0.18 17/0.15 |
0.75 |
0.76 |
0.69 |
2.27 |
±0.10 |
59.4 |
21 |
0.412 |
17/0.18 |
0.88 |
0.76 |
0.69 |
2.40 |
±0.10 |
46.9 |
20 |
0.519 |
21/0.18 10/0.26 7/0.31 |
0.96 |
0.76 |
0.69 |
2.46 |
±0.10 |
36.7 | |
|
|
|
|
 |
|
|